Technical Specifications - As Of 08-01-08
 
Loading Dock
  • Semi Trailer Level
  • No Dock Plate
  • 75' Push to the Stage Level on 2% Grade
  • After Push you enter USR at stage level
  • Loading doors are 8'-8'
 
Seating Capacity
  • Main floor - 776
  • Boxes - 38
  • Balcony - 438
  • Total 1252
 
Stage Dimensions
  • Back wall to Proscenium 24'
  • SR Wall to SL Wall 52'
  • Proscenium to Front of Pit Cover 8'
  • Proscenium Height 22'6"
  • Proscenium Width 34'4"
 
House Fly System
  • 52' to the grid
  • 28 Hemp and Sand Bag Line sets
  • 3 Drill Operated Winches (electrics)
 
Soft Goods
  • 3 Sets of Side Tabs 6'-19'
  • 3 Sets of Legs 4'-19'
  • 1 Mid Stage Traveler 36'6"-19'
  • 1 Full Stage Black 36'6"-19
  • 1 Valance (Scalloped) Movable Up or Down
  • 1 Main Curtain (Travel or Geatein)
  • House hang plot upon request
 
Pit Cover
  • Stageright
  • This is Removable upon Request
  • 1 Stair Unit (can be placed anywhere along the front edge of the pit cover
 
Company Switches
  • SL 20' of The Stage is a Catwalk with 200amp single phase for Sound
  • SL 20' of The Stage is a Catwalk with 400amp Three phase for Lighting
  • USR on the loading ramp is 2-50amp single phase for shore power
 
Storage
  • USR is a 20'-24' room that is just of the load in entrance
 
Dressing Rooms
  • SL upstairs is a large chorus w/bathroom attached
  • SL downstairs is a med chorus - bathroom in the hall
  • SL downstairs is a star w/ sink but shares bathroom w/ chorus
  • SR upstairs star w/bathroom
  • SR downstairs star w/bathroom
  • Storage room can be used as dressing room upon request
 
Mix Position
  • 75' from stage HR of center
 
House Sound
  • 2 Stacks of McCauly n-line SR and SL
  • 12 top boxes and 4 bottoms
  • All QSC Powerlite amplifiers
  • 1-Allen and Heath 2200 FOH desk
  • 2 sm 58
  • 2 beta sm 57
  • 4 boom stands
  • 1 cd player
  • 1 3rd octive EQ on the stacks
  • Hearing impeared units available
 
House Lighting
  • 288 channels of etc sensor dimming
  • 1 obsession 2 w/2 monitors and keyboards
  • 16-19 degree S4 Lekos (on stage)
  • 12-26 degree S4 Lekos (on stage)
  • 11-36 degree S4 Lekos (on stage)
  • 11-19 degree S4 Barrels (on stage)
  • 48-S4 par 64 (on stage)
  • 8-S4 12 circuit mutipar strips (on stage)
  • 24-15 to 30 degree S4 zooms (FOH)
  • 12-19 Degree S4 Lekos (box booms HR and HL)
  • 2- Lycian 1272 Starklite II
  • Theatrical circuit layout upon request
 
Spot Position
  • HR and HL top corners of the balcony
 